RF
Cable
Type |
RG-402/U |
141 TP |
SS402 |
RG-405/U |
085 TP |
047TP |
Mil
17 No. |
M17/130
- RG402 |
M17/130
-00001 |
M17/130
- RG402 |
M17/133
- RG405 |
M17/133
-00001 |
M17/151
-00001 |
DIMENSIONS(mm) |
|
|
|
|
|
|
Inner Conductor |
0.92 |
0.92 |
0.93 |
0.51 |
0.51 |
0.29 |
Insulation |
2.98 |
2.98 |
2.97 |
1.68 |
1.68 |
0.94 |
Outer Conductor |
3.58 |
3.58 |
3.58 |
2.20 |
2.20 |
1.19 |
Jacket |
None |
None |
4.14 |
None |
None |
None |
MATERIAL |
|
|
|
|
|
|
Inner
Conductor |
Silver-Coated
Copper Clab
Steel |
Silver-Coated
Copper Clab
Steel |
Silver-Coated
Copper Clab
Steel |
Silver-Coated
Copper Clab
Steel |
Silver-Coated
Copper Clab
Steel |
Silver-Coated
Copper Clab
Steel |
Insulation |
PTFE Type F-1 |
PTFE Type F-1 |
PTFE Type F-1 |
PTFE Type F-1 |
PTFE Type F-1 |
PTFE Type F-1 |
Outer Conductor |
Copper Tin
Composite
Shield |
Tin Plated
Copper-Tube |
Silver-Coated
Copper &
Copper Strip |
Copper Tin
Composite
Shield |
Tin Plated
Copper-Tube |
Tin Plated
Copper-Tube |
Jacket |
None |
None |
FEP |
None |
None |
None |
CABLE
CONSTRUCTION |
|
|
|
|
|
|
Inner Conductor |
Solid |
Solid |
Solid |
Solid |
Solid |
Solid |
Insulation |
Solid |
Solid |
Solid |
Solid |
Solid |
Solid |
Outer Conductor |
Wrap & Tin
Braid |
Solid |
Helical
Wrap/Braid |
Wrap & Tin
Braid |
Solid |
Solid |
WEIGHT
(Max. Kg/100 m) |
4.5 |
4.67 |
5.3 |
1.8 |
2.0 |
0.57 |
TEMPERATURE
Coverage
|
|
|
|
|
|
|
(Min. to Max., ¡É) |
-40 to +200 |
-40 to +125 |
-65 to +200 |
-40 to +200 |
-40 to +125 |
-40 to +150 |
Freq.
(Max. §×) |
20 |
20 |
18 |
20 |
20 |
20 |
ATTENUATION
(dB/100 ft) |
|
|
|
|
|
|
Freq.(§Ö) 400 |
7.1 |
7.8 |
7.2 |
13.5 |
13 |
23 |
1000 |
12 |
11.3 |
13 |
22 |
22 |
34.2 |
3000 |
21 |
21 |
22 |
37 |
35 |
55 |
5000 |
29 |
28 |
30 |
52 |
50 |
78.8 |
10000 |
45 |
42 |
45 |
80 |
80 |
113.8 |
POWER HANDLING
(Watts) |
|
|
|
|
|
|
Freq.(§Ö) 400 |
483 |
483 |
720 |
220 |
220 |
69 |
1000 |
336 |
336 |
440 |
130 |
130 |
47.7 |
3000 |
200 |
200 |
260 |
74 |
74 |
30.5 |
5000 |
94.6 |
94.6 |
170 |
54 |
54 |
20.7 |
10000 |
62.7 |
62.7 |
110 |
35 |
35 |
9.9 |
V.S.W.R. (Max) |
|
|
|
|
|
|
Freq.(§Ö) 500 |
1.07 |
1.07 |
1.15 |
1.08 |
1.08 |
1.08 |
1000 |
1.08 |
1.08 |
1.15 |
1.09 |
1.09 |
1.17 |
3000 |
1.12 |
1.12 |
1.25 |
1.13 |
1.12 |
1.19 |
10000 |
1.17 |
1.17 |
1.25 |
1.22 |
1.22 |
1.29 |
VOLTAGE RATING
(Volts RMS) |
|
|
|
|
|
|
Continuous Working
Voltage (Max) |
1900 |
1900 |
1900 |
1500 |
1500 |
1000 |
Voltage Withstanding
(+10%-0%) |
5000 |
5000 |
- |
5000 |
5000 |
2000 |
Corona Extinction
Voltage (Min) |
1900 |
1900 |
- |
1500 |
1500 |
1000 |
CHARACTERISTIC |
|
|
|
|
|
|
Impedance(Ohms) |
50 |
50 |
50 |
50 |
50 |
50 |
MINIMUM INSIDE
BEND |
|
|
|
|
|
|
(Radius, In.) |
- |
0.075 |
0.8 |
- |
0.05 |
0.05 |
VELOCITY OF
PROPAGATION |
|
|
|
|
|
|
(Nom., %) |
69.5 |
69.5 |
70 |
69.5 |
69.5 |
69.5 |
SHIELDING
EFFICENCY, dB/ft |
>100 |
>100 |
>100 |
>100 |
>100 |
>100 |